Wooden floor boards

 

Floor installation

Download floor installation as PDF

Basic installation

Advisable for upper floors and for lower installation heights

Basic installation nderfloor heating with wooden floor boards
  • Wooden floor boards
    15 - 22 mm
  • GreenLine system panel + MVR heating pipe
    30 mm
  • Sleepers
  • Edge insulation strips
  • Total installation height approx..
    45 - 52 mm

Extended installation with additional insulation

Advisable for the ground floor or cellar and for larger installation heights

Extended installation nderfloor heating with wooden floor boards
  • Wooden floor boards
    15 - 22 mm
  • GreenLine system panel + MVR heating pipe
    30 mm
  • Sleepers
  • Additional insulation
    ≥ 30 mm
  • Edge insulation strips
  • Total installation height approx.
    ≥ 75 - 82 mm

 

Technical data Basic installation Extended installation
Heating circuit length ø 80 – 90 m (~ 15 m²) | max. 110 m
Additional insulation 20 – 60 mm wood fibre insulation ≥ 150 kPa
Weight 22 - 33 kg / m² (depending on the thickness of the wooden boards)
Surface load | Point load 2.0 kN / m² | 1.0 kN 2.0 kN / m² | 1.0 kN
Minimum thermal conductivity resistance R ≥ 0.75 m²K / W
DIN EN 1264: Floors in mezzanine floors
≥ 1.25 m²K / W
DIN EN 1264: Floors on ground floors / cellars

 

Important information
Base requirements
(accord. DIN 18202 table 3, line 4)
Bases must be level, stable and able to take a load.
Unevenness > 3 mm at 1 m length must be compensated.
Compensation of unevenness
(according to degree of unevenness)
0 – 10 mm: Floor levelling paste
10 – 50 mm: Floor levelling paste, thin screed, dry filling
from 40 mm: Bulk filling, light concrete
Special aspects Protect wooden floor boards against rising moisture according to the manufacturer's instructions
Choose sleepers according to the manufacturer's instructions.
Avoid an air gap between the system panel and boards (boards must be supported).

 

Performance table *

Floor covering Room temperature Heating water temperature
30°C 35°C 40°C 45°C
W / m² ST W / m² ST W / m² ST W / m² ST
Floor covering
Wooden floor boards on counte battens
20 °C 24,9 22,6 37,8 23,9 50,6 25,2 63,4 26,5
24 °C 14,3 25,5 27,5 26,8 40,4 28,2 53,2 29,5
W / m² – System heating output
ST – Surface temperature
* The area of the underfloor heating is reduced by the surface ratio of sleepers

 

Sample laying plan

Sample laying plan underfloor heating