Tiles

 

Floor installation

Download floor installation as PDF

Basic installation

Advisable for upper floors and for lower installation heights

Basic installation GreenLine underfloor heating with tiles
  • Tiles (incl. adhesive)
    ≥ 10 mm
  • QuickFloor FL
    7 mm
  • Adhesive
  • GreenLine system panel + MVR heating pipe
    30 mm
  • Edge insulation strips
  • Total installation height approx.
    ≥ 47 mm

Extended installation with additional insulation

Advisable for the ground floor or cellar and for larger installation heights

Extended floor installation GreenLine underfloor heating with tiles
  • Tiles (incl. adhesive)
    ≥ 10 mm
  • QuickFloor FL
    7 mm
  • Adhesive
  • GreenLine system panel + MVR heating pipe
    30 mm
  • OSB panel
    22 mm
  • Additional insulation
    ≥ 30 mm
  • Edge insulation strips
  • Total installation height approx.
    ≥ 99 mm

 

Technical data Basic installation Extended installation
Heating circuit length ø 80 – 90 m (~ 15 m²) | max. 110 m
Additional insulation 20 – 40 mm wood fibre insulation ≥ 150 kPa
Gewicht 16 – 34 kg / m2 (without floor covering)
Surface load | Point load 1.5 kN / m² | 1.0 kN 1.5 kN / m² | 1.0 kN
Minimum thermal conductivity resistance R ≥ 0.75 m²K / W
DIN EN 1264: Floors in mezzanine floors
1.25 m²K / W
DIN EN 1264: Floors on ground floors / cellars

 

Important information
Base requirements >br />(accord. DIN 18202 table 3, line 4) Bases must be level, stable and able to take a load.
Unevenness > 3 mm at 1 m length must be compensated.
Compensation of unevenness
(according to degree of unevenness)
0 – 10 mm: Floor levelling paste
10 – 50 mm: Floor levelling paste, thin screed
from 40 mm: Light concrete
Special aspects Fix QuickFloor FL on heating elements. Tape joints with textile tape.
Only attach tiles with Mapei Elastorapid. Only fill joints with Mapei UltracolorPlus.
Reinforce doorways and kitchen units with Stabi Fix.
Use plastic coated, cementitious sealing slurries such as Mapelastic or Monolastic by Mapei for waterproofing in damp rooms.

 

Performance table

Floor covering Room temperature Heating water temperature
30°C 35°C 40°C 45°C
W / m² ST W / m² ST W / m² ST W / m² ST
Floor covering
Rλ,B = 0,00 m² K / W
Tiles
20 °C 41.0 23.8 62.2 25.8 83.2 27.7 104.3 29.7
24 °C 23.6 26.2 45.2 28.2 66.4 30.1 87.4 32.1
Floor covering
Rλ,B = 0,015 m² K / W
Tiles
20 °C 38.1 23.5 57.8 25.4 77.4 27.2 97.0 29.0
24 °C 21.9 26.0 42.1 27.9 61.8 29.7 81.4 31.5
W / m² – System heating performance
ST – Surface temperature

 

 

Installation

 

 

Sample laying plan

Sample laying plan underfloor heating

Download floor installation as PDF

 

Contact

If you have any questions, feel free to contact us:

support[at]quick-tec.com

Business Hours

Our QuickTec Online-Shop is available 24 hours a day.

Our support hotline is available Mo-Fr: 9am to 4pm (49) 30 | 577 0188 40