Carpet | Vinyl | PVC

 

Floor installation

Download floor installation as PDF

Basic installation

Advisable for upper floors and for lower installation heights

Basic installation underfloor heating with carpet, linoleum, PVC and vinyl design flooring
  • Carpet | Design floor covering
    ≥ 3 mm
  • QuickFLoor TK
    10 mm
  • GreenLine system panel + MVR heating pipe
    30 mm
  • Edge insulation strips
  • Total installation height approx.
    ≥ 43 mm

Extended installation with additional insulation

Advisable for the ground floor or cellar and for larger installation heights

extended installation underfloor heating with carpet, linoleum, PVC and vinyl design flooring
  • Carpet | Design floor covering
    ≥ 3 mm
  • QuickFloor TK
    10 mm
  • GreenLine system panel + MVR heating pipe
    30 mm
  • OSB panel
    18 mm
  • Additional insulation
    ≥ 30 mm
  • Edge insulation strips
  • Total installation height approx.
    ≥ 91 mm

 

Technical data Basic installation Extended installation
Heating circuit length ø 80 – 90 m (~ 15 m²) | max. 110 m
Additional insulation 20 – 60 mm wood fibre insulation ≥ 150 kPa
Weight 18 - 35 kg / m² (without floor covering)
Surface load | Point load 1.5 kN / m² | 1.0 kN 1.5 kN / m² | 1.0 kN
Minimum thermal conductivity resistance R ≥ 0.75 m²K / W
DIN EN 1264: Floors in mezzanine floors
≥ 1.25 m²K / W
DIN EN 1264: Floors on ground floors/cellars

 

Important information
Base requirements
(accord. DIN 18202 table 3, line 4)
Bases must be level, stable and able to take a load.
Unevenness > 3 mm at 1 m length must be compensated.
Compensation of unevenness
(according to degree of unevenness)
0 – 10 mm: Floor levelling paste
10 – 50 mm: Floor levelling paste, thin screed, dry filling
from 40 mm: Bulk filling, light concrete
Special aspects Provide heavy furniture at edges or in corners with an additional support area (15 x 15 cm).
Reinforce doorways and kitchen units with Stabi Fix.
Cover the heating elements with a vapour barrier (PE foil) if there is residual moisture in the base.

 

Performance table

Floor covering Room temperature Heating water temperature
30°C 35°C 40°C 45°C
W / m² ST W / m² ST W / m² ST W / m² ST
Floor covering
Rλ,B = 0.05 m² K / W
Carpet, Design floor covering
20 °C 30.9 22.9 46.9 24.3 62.8 25.8 78.6 27.3
24 °C 17.8 25.6 34.1 27.2 50.1 28.6 65.9 30.1
Floor covering
Rλ,B = 0.10 m² K / W
Carpet, Design floor covering
20 °C 26.0 22.4 39.5 23.7 52.9 24.9 66.2 26.1
24 °C 15.0 25.4 28.7 26.7 42.2 27.9 55.5 29.1
W / m² – System heating output
ST – Surface temperature

 

Installation

 

Sample laying plan

Sample laying plan underfloor heating

Download floor installation as PDF

 